Fire safety inspection requirements in Latvia
What a fire inspection has to cover in Latvia — the instruments that impose it, and the clause each check is cited to.
1 instrument · 16 requirements · 18 checks · authoritative language: LV
Requirements below are shown in LV — the legally authoritative language in Latvija — with an English translation beneath. The translation is a convenience and is never the requirement itself.
The instruments we cite
Ugunsdrosibas, ugunsdzesibas un glabsanas darbu likums (speka no 2025-11-13 -- objekta ipasnieka un valditaja pienakumi ugunsdrosibas joma; · edition Ugunsdrosibas, ugunsdzesibas un glabsanas darbu likums (pienemts 2025-10-16, speka no 2025-11-13), speka esosa redakcija; Ministru kabineta 2016. gada 19. aprila noteikumi Nr. 238 'Ugunsdrosibas noteikumi', speka esosa (konsolideta) redakcija no 2025-07-01 (speka limdz 2027-01-01, zaude speku 2027-01-02); Ministru kabineta 2015. gada 30. junija noteikumi Nr. 333 'Noteikumi par Latvijas buvnormativu LBN 201-15 Buvju ugunsdrosiba', ar grozijumiem; LVS EN standarti speka esosajas redakcijas (LVS EN 3, LVS EN 671, LVS EN 1838, LVS EN 50172, LVS EN 54, LVS EN 12845, LVS EN 12101, LVS EN ISO 7010, LVS EN 13501)
What an inspection covers
Latvijas būvnormatīvs LBN 201-15 'Būvju ugunsdrošība' (MK noteikumi Nr. 333) -- ugunsdrošības nodalījumi, ugunsizturība; Ministru kabineta noteikumi Nr. 238 'Ugunsdrošības noteikumi' -- uzturēšana; LVS EN 13501 (ugunsdrošības klasifikācija)
LBN + STANDARTS: Ugunsdrošības nodalījumu norobežojošām un nesošām konstrukcijām, ugunsdrošības sienām un pārsegumiem ar to caurvadu hermetizāciju, ugunsdrošības durvīm un aizbīdņiem jābūt nebojātiem, bez neaizhermetizētiem caurumiem; nesošo un norobežojošo konstrukciju ugunsizturībai jābūt saglabātai, un izmantotajiem būvizstrādājumiem jāatbilst noteiktajai degtspējas (ugunsdrošības) klasei. Juridiskais pamats: ugunsdrošības nodalījumi un ugunsizturība LBN 201-15 (LBN); uzturēšana MK noteikumi Nr. 238 (MK noteikumi); būvizstrādājumu klasifikācija LVS EN 13501 (standarts).
LBN + STANDARD: Fire-compartment-enclosing and load-bearing structures, fire walls and floors with sealing of their penetrations, fire doors and dampers must be intact and free of unsealed openings; the fire resistance of load-bearing and separating structures must be preserved, and construction products used must meet the prescribed reaction-to-fire (fire) class. Legal basis: fire compartments and fire resistance LBN 201-15 (LBN); maintenance Cabinet Regulation No. 238 (Cabinet regulation); construction-product classification LVS EN 13501 (standard).
Checks on this requirement
- Are fire walls/floors intact, penetrations sealed and fire doors/dampers functional (no open, unsealed openings)?
- Is the fire resistance of load-bearing/separating structures preserved, and do fire doors self-close with the required fire class?
Latvijas būvnormatīvs LBN 201-15 'Būvju ugunsdrošība' (MK noteikumi Nr. 333) -- ārējais ugunsdzēsības ūdensapgāde; Ministru kabineta noteikumi Nr. 238 'Ugunsdrošības noteikumi' -- hidrantu uzturēšana
LBN + MK NOTEIKUMI: Objektu apkalpojošajam ārējam ugunsdzēsības ūdensapgādei (ārējie ugunsdzēsības hidranti, ūdens rezervuāri vai ūdens ņemšanas vietas) jābūt kārtībā, apzīmētai, pieejamai ugunsdzēsības automašīnām un jānodrošina nepieciešamais ūdens daudzums ugunsgrēka dzēšanai; hidranti periodiski jāpārbauda, ziemā -- jāaizsargā pret aizsalšanu. Juridiskais pamats: ārējais ugunsdzēsības ūdensapgāde LBN 201-15 (LBN); hidrantu uzturēšana MK noteikumi Nr. 238 (MK noteikumi).
LBN + CABINET REGULATION: The external fire-water supply serving the object (external fire hydrants, water reservoirs or water-draw points) must be sound, marked, accessible to fire appliances and ensure the required water volume for firefighting; hydrants are periodically checked and, in winter, protected from freezing. Legal basis: external fire-water supply LBN 201-15 (LBN); hydrant maintenance Cabinet Regulation No. 238 (Cabinet regulation).
Checks on this requirement
- Are external fire hydrants/water-draw points sound, marked, accessible and periodically checked (ensuring the required water volume)?
Ministru kabineta 2016. gada 19. aprīļa noteikumi Nr. 238 'Ugunsdrošības noteikumi' (spēkā esošā redakcija no 2025-07-01) -- objekta ugunsdrošības instrukcija un atbildīga persona par ugunsdrošību; Ugunsdrošības, ugunsdzēsības un glābšanas darbu likums (spēkā no 2025-11-13) -- īpašnieka un valdītāja pienākumi
MK NOTEIKUMI: Objekta (uzņēmuma, iestādes, organizācijas) īpašniekam vai valdītājam ir jāizstrādā un jāapstiprina objekta ugunsdrošības instrukcija, kas atbilst objekta specifikai un ugunsbīstamībai, kā arī jāieceļ atbildīga persona par ugunsdrošību. Instrukcija nosaka ugunsdrošības kārtību, darbinieku pienākumus, rīcību ugunsgrēka gadījumā un evakuācijas kārtību; instrukcijai jābūt aktuālai un pieejamai ugunsdrošības pārbaudes laikā. Juridiskais pamats: ugunsdrošības instrukcija un atbildīga persona MK noteikumi Nr. 238 (MK noteikumi); īpašnieka un valdītāja pienākumi Ugunsdrošības, ugunsdzēsības un glābšanas darbu likums (likums).
CABINET REGULATION: The owner or manager of the object (enterprise, institution, organisation) must draw up and approve the object's fire-safety instruction matching the object's nature and fire hazard, and must appoint a person responsible for fire safety. The instruction sets the fire-safety regime, staff duties, actions in case of fire and the evacuation procedure; it must be current and available at a fire-safety inspection. Legal basis: fire-safety instruction and responsible person Cabinet Regulation No. 238 (Cabinet regulation); owner and manager duties Fire Safety, Fire-Fighting and Rescue Work Law (statute).
Checks on this requirement
- Does the object have a current, approved fire-safety instruction, and is a person responsible for fire safety appointed?
Ministru kabineta noteikumi Nr. 238 'Ugunsdrošības noteikumi' (spēkā esošā redakcija no 2025-07-01) -- darbinieku ugunsdrošības instruktāžas, apmācība un praktiskās evakuācijas mācības
MK NOTEIKUMI: Objekta darbinieki ir jāinstruē un jāapmāca ugunsdrošības jautājumos (ievadinstruktāža un atkārtotas instruktāžas), viņiem jāzina rīcība ugunsgrēka gadījumā un evakuācijas kārtība; noteiktajos objektos periodiski jāorganizē praktiskās evakuācijas mācības, un instruktāžas un mācības jādokumentē. Juridiskais pamats: instruktāžas, apmācība un evakuācijas mācības MK noteikumi Nr. 238 (MK noteikumi).
CABINET REGULATION: Object staff must be instructed and trained in fire-safety matters (induction and repeat briefings), must know the actions in case of fire and the evacuation procedure; in prescribed objects practical evacuation drills must be organised periodically, and briefings and training documented. Legal basis: briefings, training and evacuation drills Cabinet Regulation No. 238 (Cabinet regulation).
Checks on this requirement
- Have staff been briefed on fire safety and have practical evacuation drills been organised (documented)?
Ministru kabineta noteikumi Nr. 238 'Ugunsdrošības noteikumi' (spēkā esošā redakcija no 2025-07-01) -- evakuācijas plāni un to izvietošana
MK NOTEIKUMI: Noteiktu lietošanas veidu un cilvēku skaita objektos ir jāizstrādā un redzamās vietās jāizvieto evakuācijas plāni, kuros norādīti evakuācijas ceļi, izejas, ugunsdrošības aprīkojuma atrašanās vietas un rīcība ugunsgrēka gadījumā; plāniem jāatbilst objekta faktiskajam izkārtojumam un jābūt saprotamiem. Juridiskais pamats: evakuācijas plāni MK noteikumi Nr. 238 (MK noteikumi).
CABINET REGULATION: In objects of the prescribed use type and occupancy, evacuation plans must be drawn up and posted in visible places, showing escape routes, exits, locations of fire-safety equipment and actions in case of fire; the plans must match the object's actual layout and be understandable. Legal basis: evacuation plans Cabinet Regulation No. 238 (Cabinet regulation).
Checks on this requirement
- Are evacuation plans drawn up and posted in visible places, and do they match the object's actual layout?
Ministru kabineta noteikumi Nr. 238 'Ugunsdrošības noteikumi' (spēkā esošā redakcija no 2025-07-01) -- ugunsdzēsības aparātu nodrošinājums un tehniskā apkope; LVS EN 3 (ugunsdzēsības aparāti)
MK NOTEIKUMI + STANDARTS: Objekta jānodrošina pietiekams skaits piemērota tipa ugunsdzēsības aparātu atbilstoši telpu lietošanas veidam un ugunsbīstamībai, labi redzamās un viegli pieejamās vietās; ugunsdzēsības aparātiem jābūt tehniski kārtībā, un tiem periodiski jāveic tehniskā apkope (pārbaude). Juridiskais pamats: ugunsdzēsības aparātu nodrošinājums un tehniskā apkope MK noteikumi Nr. 238 (MK noteikumi); ugunsdzēsības aparātiem izvirzītās prasības LVS EN 3 (standarts).
CABINET REGULATION + STANDARD: The object must have a sufficient number of the correct type of fire extinguishers for the premises' use and fire hazard, in clearly visible and readily accessible places; extinguishers must be technically sound and undergo periodic maintenance (inspection). Legal basis: provision and maintenance of extinguishers Cabinet Regulation No. 238 (Cabinet regulation); extinguisher requirements LVS EN 3 (standard).
Checks on this requirement
- Are there enough suitable extinguishers, readily accessible, with a valid periodic maintenance (inspection)?
Ministru kabineta noteikumi Nr. 238 'Ugunsdrošības noteikumi' (spēkā esošā redakcija no 2025-07-01) -- ugunsnedrošu (degtspējīgu) šķidrumu, gāzu un gāzes balonu glabāšana
MK NOTEIKUMI: Ugunsnedrošas un bīstamas vielas (degtspējīgi šķidrumi, gāzes, gāzes baloni) jāglabā tam paredzētās, ventilētās un aizsargātās vietās, pieļaujamos daudzumos, atstatus no aizdegšanās avotiem un evakuācijas ceļiem; glabāšanai un lietošanai jāatbilst noteiktajām prasībām. Juridiskais pamats: ugunsnedrošu un bīstamu vielu glabāšana MK noteikumi Nr. 238 (MK noteikumi).
CABINET REGULATION: Flammable and dangerous substances (flammable liquids, gases, gas cylinders) must be stored in designated, ventilated and protected places, in permitted quantities, away from ignition sources and escape routes; storage and use must meet the set requirements. Legal basis: storage of flammable and dangerous substances Cabinet Regulation No. 238 (Cabinet regulation).
Checks on this requirement
- Are flammable/dangerous substances and gas cylinders stored in a designated ventilated place, in the permitted quantity, away from ignition sources and escape routes?
Ministru kabineta noteikumi Nr. 238 'Ugunsdrošības noteikumi' -- aizdegšanās avotu pārvaldība un elektroietaišu lietošana; Ugunsdrošības, ugunsdzēsības un glābšanas darbu likums -- vispārējie pienākumi
MK NOTEIKUMI: Objekta elektroinstalācijai un elektroietaisēm jābūt tehniski kārtībā un jālieto atbilstoši to ekspluatācijas prasībām, lai tās nekļūtu par aizdegšanās avotu (aizliegta pārslodze, pagaidu vai bojātas instalācijas, degtspējīgu materiālu glabāšana pie sakarsētām virsmām). Aizdegšanās avoti jāpārvalda, un zināmi elektroinstalācijas trūkumi jānovērš. Juridiskais pamats: aizdegšanās avotu pārvaldība un elektroietaišu lietošana MK noteikumi Nr. 238 (MK noteikumi); vispārējie pienākumi Ugunsdrošības, ugunsdzēsības un glābšanas darbu likums (likums).
CABINET REGULATION: The object's electrical installation and appliances must be technically sound and used per their operating requirements so they do not become an ignition source (no overload, temporary or damaged wiring, or combustible materials stored near heated surfaces). Ignition sources must be controlled and known electrical faults remedied. Legal basis: control of ignition sources and use of electrical installations Cabinet Regulation No. 238 (Cabinet regulation); general duties Fire Safety, Fire-Fighting and Rescue Work Law (statute).
Checks on this requirement
- Is the electrical installation sound (no overload, overheating or temporary wiring), and are combustibles kept away from ignition sources?
Ministru kabineta noteikumi Nr. 238 'Ugunsdrošības noteikumi' -- avārijas (drošības) apgaismojums; LVS EN 1838 / LVS EN 50172 (avārijas apgaismojums)
MK NOTEIKUMI + STANDARTS: Kur noteikts, evakuācijas ceļos jāierīko avārijas (drošības) apgaismojums, kas, zudot normālajai elektroapgādei, automātiski ieslēgas un apgaismo evakuācijas ceļu noteiktu laiku; kā ugunsdrošības pasākums tas periodiski jāpārbauda un jāuztur. Juridiskais pamats: avārijas apgaismojuma prasība MK noteikumi Nr. 238 (MK noteikumi); apgaismojuma līmenis un darbības ilgums LVS EN 1838 un LVS EN 50172 (standarts).
CABINET REGULATION + STANDARD: Where prescribed, escape routes must have emergency (safety) lighting that, on loss of normal power, switches on automatically and illuminates the escape route for the set time; as a fire-safety measure it must be periodically tested and maintained. Legal basis: emergency-lighting requirement Cabinet Regulation No. 238 (Cabinet regulation); illuminance and duration LVS EN 1838 and LVS EN 50172 (standard).
Checks on this requirement
- Does emergency lighting switch on when power fails, illuminate the route for the set time, and has it been tested?
Ministru kabineta noteikumi Nr. 238 'Ugunsdrošības noteikumi' -- dūmu un siltuma vadības (izvades) sistēmas uzturēšana; LVS EN 12101 (dūmu un siltuma vadība)
MK NOTEIKUMI + STANDARTS: Kur ierīkota dūmu un siltuma vadības (izvades) sistēma, tai kā ugunsdrošības pasākumam jābūt uzturētai darboties spējīga un periodiski jāpārbauda (dūmu lūkas/logi un ventilatori pārbaudot iedarbojas, dūmu izvades un pieplūdes gaisa atveres brīvas, vadība un rezerves barošana kārtībā). Juridiskais pamats: dūmu un siltuma vadības sistēmas uzturēšana MK noteikumi Nr. 238 (MK noteikumi); sistēmas elementi un pārbaudes LVS EN 12101 (standarts).
CABINET REGULATION + STANDARD: Where a smoke and heat control (exhaust) system is installed, as a fire-safety measure it must be kept operational and periodically tested (smoke hatches/windows and fans operate on test, smoke-exhaust and make-up air openings clear, control and backup power in order). Legal basis: maintenance of smoke and heat control system Cabinet Regulation No. 238 (Cabinet regulation); system elements and tests LVS EN 12101 (standard).
Checks on this requirement
- Does the smoke and heat control system operate on test (hatches/windows/fans), are the exhaust and make-up air openings clear, and is it maintained?
Ministru kabineta noteikumi Nr. 238 'Ugunsdrošības noteikumi' -- evakuācijas ceļu un izeju brīva pieejamība; Latvijas būvnormatīvs LBN 201-15 'Būvju ugunsdrošība' (MK noteikumi Nr. 333) -- evakuācijas ceļi un durvis
MK NOTEIKUMI + LBN: Evakuācijas ceļiem, izejām un piekļuvei tām jābūt pastāvīgi brīvām, neaizkrautām ar priekšmetiem vai degtspējīgiem materiāliem un pietiekamas caurlaidības, lai cilvēki varētu ātri un droši evakuēties. Evakuācijas izeju durvīm jāatveras viegli no iekšienes bez atslēgas, un, kur noteikts, jāatveras evakuācijas virzienā. Juridiskais pamats: evakuācijas ceļu brīva pieejamība MK noteikumi Nr. 238 (MK noteikumi); evakuācijas ceļu un durvju prasības LBN 201-15 (LBN).
CABINET REGULATION + LBN: Escape routes, exits and their approaches must be kept clear at all times, not obstructed by objects or combustibles, and of adequate capacity so people can escape quickly and safely. Emergency exit doors must open easily from inside without a key and, where prescribed, open in the escape direction. Legal basis: clear escape routes Cabinet Regulation No. 238 (Cabinet regulation); escape-route and door requirements LBN 201-15 (LBN).
Checks on this requirement
- Are escape routes and exits clear, unobstructed and of adequate capacity throughout?
- Do emergency exit doors open easily from inside without a key and swing the required way?
Ministru kabineta noteikumi Nr. 238 'Ugunsdrošības noteikumi' -- iekšējā ugunsdzēsības ūdensapgāde (ugunsdzēsības krāni) un to uzturēšana; LVS EN 671 (ugunsdzēsības šļūteņu sistēmas ar spolēm)
MK NOTEIKUMI + STANDARTS: Kur noteikts, objekta jāierīko iekšējā ugunsdzēsības ūdensapgāde (ugunsdzēsības krāni ar šļūteņu sistēmām) ar pietiekamu spiedienu un ūdens daudzumu sākotnējai ugunsgrēka dzēšanai, viegli pieejamās vietās; kā ugunsdrošības pasākums tiem jābūt kārtībā, jāuztur un periodiski jāpārbauda. Juridiskais pamats: iekšējā ugunsdzēsības ūdensapgāde un tā uzturēšana MK noteikumi Nr. 238 (MK noteikumi); šļūteņu sistēmu prasības LVS EN 671 (standarts).
CABINET REGULATION + STANDARD: Where prescribed, the object must have an internal fire-water supply (fire taps with hose systems) with adequate pressure and water flow for first-aid firefighting, in readily accessible places; as a fire-safety measure they must be in order, maintained and periodically tested. Legal basis: provision and maintenance of internal fire-water supply Cabinet Regulation No. 238 (Cabinet regulation); hose-system requirements LVS EN 671 (standard).
Checks on this requirement
- Is the internal fire-water supply (fire taps) provided where required, with adequate pressure/flow, readily accessible and maintained?
Ministru kabineta noteikumi Nr. 238 'Ugunsdrošības noteikumi' -- stacionāras ugunsdzēsības sistēmas uzturēšana; LVS EN 12845 (sprinkleri)
MK NOTEIKUMI + STANDARTS: Kur ierīkota stacionāra ugunsdzēsības sistēma (sprinkleru, gāzes, putu vai ūdens smidzināšanas), tai kā ugunsdrošības pasākumam jābūt gatavības un darboties spējīga stāvoklī (uzpildīta/zem spiediena, vārsti atvērti un kontrolēti, sprinkleru galvas/smidzinātāji brīvi, ūdens vai dzēšanas vielas avots un sūkņi kārtībā) un periodiski jāpārbauda un jāuztur. Juridiskais pamats: stacionāras ugunsdzēsības sistēmas uzturēšana MK noteikumi Nr. 238 (MK noteikumi); sistēmas projektēšana un uzturēšana LVS EN 12845 (standarts).
CABINET REGULATION + STANDARD: Where a fixed fire-extinguishing system (sprinkler, gas, foam or water-spray) is installed, as a fire-safety measure it must be in a ready and operational state (charged/pressurised, valves open and monitored, sprinkler heads/nozzles clear, water or agent source and pumps in order) and periodically inspected and maintained. Legal basis: maintenance of fixed extinguishing system Cabinet Regulation No. 238 (Cabinet regulation); system design and maintenance LVS EN 12845 (standard).
Checks on this requirement
- Is the fixed extinguishing system in a ready state (pressure, valves open/monitored, heads clear, water source/pumps in order) and periodically maintained?
Ministru kabineta noteikumi Nr. 238 'Ugunsdrošības noteikumi' -- ugunsdrošības un evakuācijas (drošības) zīmes; LVS EN ISO 7010 (drošības zīmes)
MK NOTEIKUMI + STANDARTS: Kur noteikts, evakuācijas ceļi un izejas jāapzīmē ar skaidrām un noturīgām evakuācijas (drošības) zīmēm, ieskaitot virziena zīmes tur, kur izeja nav tieši redzama; zīmēm jābūt nebojātām, redzamām un jāatbilst standartam. Juridiskais pamats: ugunsdrošības un evakuācijas zīmes MK noteikumi Nr. 238 (MK noteikumi); zīmju simboli LVS EN ISO 7010 (standarts).
CABINET REGULATION + STANDARD: Where prescribed, escape routes and exits must be marked with clear and durable evacuation (safety) signs, including directional signs where the exit is not directly visible; signs must be intact, visible and standard-compliant. Legal basis: fire-safety and evacuation signage Cabinet Regulation No. 238 (Cabinet regulation); sign symbols LVS EN ISO 7010 (standard).
Checks on this requirement
- Are escape routes marked with intact, visible evacuation and directional signs, including where the exit is not directly visible?
Ministru kabineta noteikumi Nr. 238 'Ugunsdrošības noteikumi' -- ugunsgrēka atklāšanas un trauksmes signalizācijas sistēmas uzturēšana; LVS EN 54 (sistēmas sastāvdaļas)
MK NOTEIKUMI + STANDARTS: Kur noteikts, objekta jāierīko ugunsgrēka atklāšanas un trauksmes signalizācijas sistēma, kas uzticami atklāj ugunsgrēku un raida signālu; kā ugunsdrošības pasākums tai jābūt darboties spējīgai un periodiski jāpārbauda un jāuztur (centrāle bez bojājumiem, detektori efektīvi, signāls dzirdams/redzams). Juridiskais pamats: ugunsgrēka atklāšanas un trauksmes signalizācijas sistēmas prasība MK noteikumi Nr. 238 (MK noteikumi); sistēmas sastāvdaļas LVS EN 54 (standarts).
CABINET REGULATION + STANDARD: Where prescribed, the object must have a fire detection and alarm system that reliably detects fire and transmits the signal; as a fire-safety measure it must be operational and periodically tested and maintained (panel without faults, detectors effective, alarm audible/visible). Legal basis: fire detection and alarm requirement Cabinet Regulation No. 238 (Cabinet regulation); system components LVS EN 54 (standard).
Checks on this requirement
- Is the fire detection and alarm system operational (panel without faults, detectors effective, alarm audible) and periodically maintained?
Ugunsdrošības, ugunsdzēsības un glābšanas darbu likums (spēkā no 2025-11-13) -- valsts ugunsdrošības uzraudzība, ko īsteno VUGD; Ministru kabineta noteikumi Nr. 238 'Ugunsdrošības noteikumi' -- prasību izpilde
LIKUMS: Objektiem tiek veikta valsts ugunsdrošības uzraudzība, ko īsteno Valsts ugunsdzēsības un glābšanas dienests (VUGD), veicot plānveida un ārpuskārtas ugunsdrošības pārbaudes; pārbaudes laikā konstatētie ugunsdrošības prasību pārkāpumi (trūkumi) ir jānovērš noteiktajos termiņos, un izpilde jādokumentē. Juridiskais pamats: valsts ugunsdrošības uzraudzība Ugunsdrošības, ugunsdzēsības un glābšanas darbu likums (likums); trūkumu novēršana MK noteikumi Nr. 238 (MK noteikumi).
STATUTE: Objects are subject to state fire supervision carried out by the State Fire and Rescue Service (VUGD) through scheduled and unscheduled fire-safety inspections; violations (deficiencies) of fire-safety requirements found at inspection must be remedied within the set deadlines, and completion documented. Legal basis: state fire supervision Fire Safety, Fire-Fighting and Rescue Work Law (statute); remedying deficiencies Cabinet Regulation No. 238 (Cabinet regulation).
Checks on this requirement
- Have deficiencies found at an earlier state fire-supervision inspection been remedied within the set deadlines?
FireCite is in beta: all 33 jurisdictions are expert-verified and shown as preview, not yet legally authoritative for compliance use.
FireCite summarises published law and standards; it is not legal advice and not a substitute for a competent fire risk assessor or the authority having jurisdiction. Regulation changes: every citation carries the edition it was checked against.
Try a free inspection
← All 33 jurisdictions