FireCite fire inspection, cited to the clause

Fire safety inspection requirements in the United Kingdom

What a fire inspection has to cover in the United Kingdom — the instruments that impose it, and the clause each check is cited to.

3 instruments · 62 requirements · 67 checks · authoritative language: EN

The instruments we cite

BS 8214:2026 · edition 2026
BS 9792:2025 · edition 2025
PAS 79-1:2020 · edition 2020

What an inspection covers

BS 8214:2026 (gaps and clearances)

Gaps and clearances around the door leaf must be within tolerance.

Checks on this requirement

BS 8214:2026 (intumescent seals)

Intumescent seals must be present, correctly fitted and undamaged.

Checks on this requirement

BS 8214:2026 (self-closing devices)

Self-closing devices must return the door to the fully closed position from any angle.

Checks on this requirement

BS 9792:2025 (communal building services) / BS 7671 (EICR) / gas safety / BS EN 62305 (lightning)

Communal building services that present a fire risk — the landlord's fixed electrical installation (EICR), communal gas/heating plant, lifts, dry-lining voids and any lightning protection — must be maintained and inspected within interval.

Checks on this requirement

BS 9792:2025 (communal fire doors) / BS 8214:2026 + BS EN 1634-1

Communal fire doors (cross-corridor, lobby, stair, riser, plant and store-room doors) must be intact, correctly specified, self-closing where required and effective at maintaining the protected route and compartment lines.

Checks on this requirement

BS 9792:2025 (compartmentation between dwellings) / Approved Document B / BS 9991

Compartmentation separating each dwelling from others and from common parts must be intact — including floors, party/separating walls, service risers, and the fire-stopping of penetrations and voids — so that a fire is contained to the flat of origin where a stay-put strategy is relied upon.

Checks on this requirement

BS 9792:2025 (emergency escape lighting) / BS 5266-1:2025

Emergency escape lighting must be provided to common escape routes and key safety points where needed for the evacuation strategy, and must operate on failure of the normal supply, with monthly function and annual duration testing.

Checks on this requirement

BS 9792:2025 (evacuation alert systems) / BS 8629:2019

Where a simultaneous evacuation strategy is used in a block of flats (typically over 18 m), an evacuation alert system to BS 8629 for use by the fire and rescue service should be provided and maintained; a stay-put block does not require one.

Checks on this requirement

BS 9792:2025 (evacuation strategy) / BS 9991 (residential fire safety design)

The building's evacuation strategy (stay-put/defend-in-place, simultaneous, or phased) must be identified, its continuing validity confirmed against the condition of compartmentation and protected routes, and any interim measures (temporary simultaneous evacuation / waking watch) recorded with an exit plan back to the intended strategy.

Checks on this requirement

BS 9792:2025 (external walls & attachments) / Fire Safety Act 2021 / PAS 9980:2022 (FRAEW)

The external wall system (cladding, insulation, cavity barriers) and attachments (balconies, windows, spandrel panels) fall within the fire risk assessment under the Fire Safety Act 2021; the level of risk they present must be considered, informed by any external-wall fire-risk appraisal (PAS 9980 FRAEW), and any balcony combustible-storage controls confirmed.

Checks on this requirement

BS 9792:2025 (facilities for firefighters) / BS 9990 (rising mains) / BS 9991 (firefighting shafts/lifts)

Firefighting facilities appropriate to the building — dry or wet rising mains, firefighting shafts and firefighters'/evacuation lifts — must be present where required, accessible and maintained; provision requirements scale with building height.

Checks on this requirement

BS 9792:2025 (fire detection & warning) / BS 5839-1:2025 (communal) + BS 5839-6 (within dwellings)

Automatic fire detection and warning must be appropriate to the building and its evacuation strategy — the correct BS 5839-1:2025 category/coverage for common parts and any simultaneous-evacuation alarm, and the correct BS 5839-6 grade within dwellings — and must reflect the BS 5839-1:2025 changes: heat detectors are no longer acceptable in rooms where people sleep (revised L2/L3), and the new Section 7 governs any extension or modification of an existing system.

Checks on this requirement

BS 9792:2025 (fire safety information to residents) / Fire Safety (England) Regs 2022 reg. 9 / RRFSO 2005 Art. 9

Residents must be given clear fire-safety instructions appropriate to the evacuation strategy (what to do in a fire, and the stay-put/evacuate basis), displayed in the common parts and provided to each dwelling, and kept up to date.

Checks on this requirement

BS 9792:2025 (flat/maisonette entrance doors) / Fire Safety Act 2021 / BS 8214:2026 + BS EN 1634-1

Flat and maisonette entrance doors (which form part of the compartmentation between each dwelling and the common escape route) must be fire-resisting and smoke-sealing (typically FD30S), self-closing, correctly hung with cold-smoke and intumescent seals intact, and free of unauthorised alterations.

Checks on this requirement

BS 9792:2025 (housing FRA — premises/building context) / RRFSO 2005 Art. 9

The building must be characterised for a housing FRA: construction and age, purpose-built vs converted, number of storeys and height, number and layout of dwellings, tenure/occupancy type (block of flats, HMO, specialised/sheltered, student), any mixed use, and the common parts covered — recorded to reflect the building as found.

Checks on this requirement

BS 9792:2025 (ignition-source & housekeeping control in common parts) / RRFSO 2005 Arts. 8-9

Ignition sources and combustible loading in the common parts must be controlled — including refuse/storage management, smoking, arson risk, and the charging/storage of e-bikes, e-scooters and mobility scooters — so that escape routes are not a fuel load or ignition point.

Checks on this requirement

BS 9792:2025 (management, recording, review & competence) / RRFSO 2005 Art. 9(6) & Art. 18 (BSA 2022 s.156) / BS 8674:2025

The FRA and all its findings must be recorded and kept up to date, a review date set (and review triggered by significant change), the Responsible Person and fire-safety management arrangements identified, and the assessment carried out by a demonstrably competent assessor; a higher-risk building must also maintain the golden thread of information.

Checks on this requirement

BS 9792:2025 (means of escape from common parts) / RRFSO 2005 Art. 14 / BS 9991

Common escape routes must be adequate for the evacuation strategy, kept clear and unobstructed, with protected stairways/lobbies maintained and final exits usable, and (where a stay-put strategy applies) stairways kept sterile.

Checks on this requirement

BS 9792:2025 (residents especially at risk / person-centred assessment) / RRFSO 2005 Art. 9

Residents whose ability to evacuate may be impaired (mobility-, sensory- or cognitively-impaired, older or very young, and those in specialised/supported housing) must be identified and a person-centred approach taken to their fire safety and escape, irrespective of building height.

Checks on this requirement

BS 9792:2025 (risk evaluation & prioritised action plan)

Each significant finding must be evaluated for risk and assigned a prioritised, time-bound remedial action, producing a clear action plan with responsibilities and target dates, and an overall risk rating for the building.

Checks on this requirement

Fire Safety (England) Regs 2022 (SI 2022/547) reg. 10

In multi-occupied residential buildings over 11 m in England, the responsible person must carry out and record quarterly checks of communal fire doors and (best-endeavours) annual checks of flat-entrance doors.

Checks on this requirement

Fire Safety (England) Regs 2022 (SI 2022/547) reg. 4

The responsible person for a high-rise residential building must install and maintain a secure information box containing the responsible person's details and the required building information, accessible to the fire and rescue service.

Checks on this requirement

Fire Safety (England) Regs 2022 (SI 2022/547) reg. 5

The responsible person for a high-rise residential building must prepare, keep up to date and share a record of the design and materials of the external walls, the level of risk they present, and any mitigating steps taken.

Checks on this requirement

Fire Safety (England) Regs 2022 (SI 2022/547) reg. 6

The responsible person for a high-rise residential building must prepare floor plans identifying lifts and key fire-fighting equipment plus a single-page building plan, keep them current, and place a hard copy in the secure information box.

Checks on this requirement

Fire Safety (England) Regs 2022 (SI 2022/547) reg. 7

The responsible person for a high-rise residential building must check firefighters' lifts, evacuation lifts and essential fire-fighting equipment at least monthly, record and share the results, and report to the fire and rescue service any fault not rectified within 24 hours.

Checks on this requirement

Fire Safety (England) Regs 2022 (SI 2022/547) reg. 8

The responsible person for a high-rise residential building must install and maintain wayfinding signage identifying floor and flat/premises numbers, visible in low light, in the common parts.

Checks on this requirement

Fire Safety (Residential Evacuation Plans) (England) Regs 2025 (SI 2025/797) regs. 5-9, 13

In England residential buildings with two or more domestic premises that are at least 18 m tall or have at least 7 storeys (or are over 11 m with a simultaneous evacuation strategy), the responsible person must identify residents whose ability to evacuate is impaired, offer each a person-centred fire risk assessment, put reasonable mitigating measures and a personal emergency evacuation plan (PEEP) in place, and prepare and annually review a building-level emergency evacuation plan.

Checks on this requirement

Fire Safety (England) Regs 2022 (SI 2022/547) reg. 10

In multi-occupied residential buildings over 11 m in England, the statutory quarterly common fire-door and annual flat-entrance-door checks must be carried out and recorded.

Checks on this requirement

Fire Safety (England) Regs 2022 (SI 2022/547) reg. 4

The responsible person for a high-rise residential building must install and maintain a secure information box containing the responsible person's details and the required building information.

Checks on this requirement

Fire Safety (England) Regs 2022 (SI 2022/547) reg. 5

The responsible person for a high-rise residential building must prepare, keep up to date and make available a record of the design and materials of the external walls, the level of risk they give rise to, and any mitigating steps taken.

Checks on this requirement

Fire Safety (England) Regs 2022 (SI 2022/547) reg. 6

The responsible person for a high-rise residential building must prepare floor plans identifying lifts and key fire-fighting equipment plus a single-page building plan, keep them current, and place a hard copy in the secure information box.

Checks on this requirement

Fire Safety (England) Regs 2022 (SI 2022/547) reg. 7

The responsible person for a high-rise residential building must check firefighters' lifts, evacuation lifts and essential fire-fighting equipment at least monthly, record and share the results, and report to the fire and rescue service any fault not rectified within 24 hours.

Checks on this requirement

Fire Safety (England) Regs 2022 (SI 2022/547) reg. 8

The responsible person for a high-rise residential building must install and maintain signage identifying floor and flat/premises numbers, visible in low light, in the common parts.

Checks on this requirement

Fire Safety (Residential Evacuation Plans) (England) Regs 2025 (SI 2025/797) regs. 5-9, 13

In England residential buildings with two or more domestic premises that are at least 18 m tall or have at least 7 storeys (or are over 11 m with a simultaneous evacuation strategy), the responsible person must identify residents whose ability to evacuate is impaired, offer each a person-centred fire risk assessment, put reasonable mitigating measures and a personal emergency evacuation plan (PEEP) in place, and prepare and annually review a building-level emergency evacuation plan.

Checks on this requirement

PAS 79-1:2020 (risk estimation & action plan)

Each significant finding must be evaluated using the PAS 79-1 likelihood x consequence risk estimator and assigned a prioritised, time-bound action, with a review date set.

Checks on this requirement

PAS 79-1:2020 A.1

The construction, layout, floors above/below ground, floor areas and use of the premises must be recorded and reflect the building as found.

Checks on this requirement

PAS 79-1:2020 A.10

Cooking facilities, including extract ductwork, must be kept clean and maintained, with suitable fire suppression / extinguishing media provided.

Checks on this requirement

PAS 79-1:2020 A.11 / BS EN 62305 (lightning protection)

Hot works and contractor activities must be controlled by permit, and any lightning protection system must be periodically tested.

Checks on this requirement

PAS 79-1:2020 A.12

Combustible materials and waste must be controlled and kept away from ignition sources and escape routes.

Checks on this requirement

PAS 79-1:2020 A.13 / DSEAR 2002 (SI 2002/2776)

Dangerous and highly flammable substances must be identified, correctly stored and controlled, and assessed under DSEAR.

Checks on this requirement

PAS 79-1:2020 A.14 / BS 9991:2024 (residential) / BS 9999:2017 (other occupancies)

Escape routes must be adequate in number, width and travel distance for the occupancy, and kept clear and unobstructed at all times. The design basis is BS 9991 for residential buildings (dwellings / blocks of flats) and BS 9999 for other occupancies.

Checks on this requirement

PAS 79-1:2020 A.15 / RRFSO 2005 Art. 14

Final exit doors must open easily in the direction of escape, without a key or special knowledge, and lead to a place of total safety.

Checks on this requirement

PAS 79-1:2020 A.16 / BS 5266-1:2025

Emergency escape lighting must be provided along escape routes and at key safety points, and function on failure of the normal supply.

Checks on this requirement

PAS 79-1:2020 A.17 / BS EN ISO 7010

Fire-safety signage — escape route, exit, fire-action and equipment-location signs — must be provided, correct and clearly visible.

Checks on this requirement

PAS 79-1:2020 A.18 / BS 5839-1:2025

The fire detection and alarm system must be appropriate to the premises' risk, give adequate warning to all occupants, and be tested and maintained.

Checks on this requirement

PAS 79-1:2020 A.19 / BS 5306-3:2017 + BS 5306-8:2023

Portable fire extinguishers of the correct type and rating must be provided, correctly sited and accessible, and maintained in serviceable condition.

Checks on this requirement

PAS 79-1:2020 A.2

The maximum number of occupants (employees, others, total) must be established for the premises and each relevant area.

Checks on this requirement

PAS 79-1:2020 A.20 / BS EN 12845:2015+A1:2019 + BS 9990:2015

Fixed firefighting systems (automatic sprinklers, dry/wet rising mains) required for the premises must be present, unobstructed and maintained within their service interval.

Checks on this requirement

PAS 79-1:2020 A.21 / BS 8214:2026

Fire doors, fire-resisting walls and compartmentation must be intact and effective.

Checks on this requirement

PAS 79-1:2020 A.22 / BESA DW/145 (2025)

Smoke-control systems and fire/smoke dampers must be present where required, unobstructed, and maintained within their inspection / drop-test interval.

Checks on this requirement

PAS 79-1:2020 A.23 / RRFSO 2005 Art. 15

A suitable, up-to-date emergency plan and evacuation procedures appropriate to the premises and its occupants must be established and communicated.

Checks on this requirement

PAS 79-1:2020 A.24 / RRFSO 2005 Art. 11, 13, 18, 22 / BS 8674:2025 (assessor competence)

A Responsible Person must be clearly identified with defined fire-safety management arrangements, including cooperation and coordination with any other responsible persons.

Checks on this requirement

PAS 79-1:2020 A.25 / RRFSO 2005 Art. 21 (training) / RRFSO 2005 Art. 15(1)(a) (drills)

Staff must receive adequate fire-safety training on induction and periodically, and evacuation drills must be carried out and recorded.

Checks on this requirement

PAS 79-1:2020 A.26 / RRFSO 2005 Art. 17

All fire safety equipment and facilities must be subject to a suitable system of maintenance and kept in efficient working order, with testing recorded in a logbook.

Checks on this requirement

PAS 79-1:2020 A.27 / RRFSO 2005 Art. 9(6) (BSA 2022 s.156)

The fire risk assessment and all of its findings must be recorded and kept up to date (every Responsible Person must record all findings since 1 October 2023).

Checks on this requirement

PAS 79-1:2020 A.3 / RRFSO 2005 Art. 9

Occupants especially at risk must be identified — including sleeping, mobility- or sensory-impaired, lone/night workers, and persons unfamiliar with the premises — and arrangements made for their evacuation.

Checks on this requirement

PAS 79-1:2020 A.4

The premises' history of fires, near-misses and false alarms must be reviewed and taken into account.

Checks on this requirement

PAS 79-1:2020 A.5 / RRFSO 2005 (SI 2005/1541)

The correct fire-safety legislation must be identified for the premises — the RRFSO 2005 duty to make a suitable and sufficient assessment, plus any Fire Safety Act 2021 / Building Safety Act 2022 duties that apply.

Checks on this requirement

PAS 79-1:2020 A.6

Fixed and portable electrical installations and equipment must be maintained in a safe condition, free from overload, damage and overdue inspection.

Checks on this requirement

PAS 79-1:2020 A.7

Controls over smoking (designated areas, signage, safe disposal) must be in place and effective.

Checks on this requirement

PAS 79-1:2020 A.8

The risk of deliberate ignition (arson) must be reduced — secure perimeter, access control and no external accumulation of combustibles.

Checks on this requirement

PAS 79-1:2020 A.9

Heating appliances and HVAC installations must be maintained, adequately guarded and kept clear of combustible materials.

Checks on this requirement

FireCite is in beta: all 33 jurisdictions are expert-verified and shown as preview, not yet legally authoritative for compliance use.